Surface calculator
Choose a product
AlphaGlass
TM
AlphaVis
TM
AlphaFlex
TM
Coming soon
Environment
Full Sun
Sunny Indoor
Pure Indoor
Units
mm
in
Module
Length
mm
+
−
Width
mm
+
−
Rated voltage
(Vmp, full sun)
V
+
−
Transparency
%
+
−
Bezel
mm
+
−
Subcells Run Along
Length
Width
Light
Indoor Illuminance
lux
+
−
Hours Indoors
h
+
−
Hours Outdoors
h
+
−
Outdoor hours assume full sun, about 100,000 lux.
Battery & Load
Battery Capacity
mAh
+
−
Battery Voltage
V
+
−
Average Load
mW
+
−
Load Units
µW
mW
Energy Delivered per Day
Daily Harvest (% of battery)
Load Covered
Battery Life
Geometry
Active Area
Active Ratio
Subcell Width
Subcells in Series
Parallel Strings
Electrical
Rated Voltage (full sun)
Open-circuit, Full Sun (max)
Open-circuit in this light
Voltage in this light
Current in this light
Battery
Power
Indoor - At the Cell
Full Sun - At the Cell, Noon
Efficiency - In / Out
Mode
Dark
Light
Request a Quote for this Design
Assumptions
Indoor efficiency follows a smooth curve through 20% at 150 lux, 24% at 400 lux and 26% at 1,000 lux, easing back toward 20% under very bright light. Outdoor efficiency is 20% under 100 mW/cm² standard sun (AlphaGlass and AlphaVis).
Room light is white LED at 300 lm/W, so 300 lux is 1 W/m² of optical power.
Outdoor energy follows a daily profile, not peak × hours: irradiance rises and falls as a half-sine across the daylight hours, which delivers 2/π (about 64%) of the peak-hours figure.
Indoor and outdoor hours together cannot exceed 24.
The converter's efficiency rises smoothly with power, from about 50% at very low power to 91% above 50 mW. MPPT tracking accuracy is 96%.
Rated voltage is the module's voltage at maximum power in full sun, as on the datasheets. The subcell count is set once from it at 0.9 V per subcell, rounded up, and stays fixed when the light changes.
In other light, each subcell delivers about 0.8 V in Sunny Indoor and 0.7 V in Pure Indoor, so the module's working voltage is lower than its rating; voltage and current are shown for the selected light.
Battery life follows the day: daylight hours, then indoor hours, then dark, with the battery starting full each morning. "Indefinite" means the battery also carries the load through every night.
The calculator uses conservative design values, lower than the certified efficiencies quoted elsewhere on this site.
Outdoor hours assume full sun, about 100,000 lux.
Battery standby is added to the load: about 0.5 µA at the battery voltage for the charger, plus self-discharge of about 2% of the battery's capacity a month.
Open-circuit voltage is about 1.1 V per subcell in full sun, 0.95 V in Sunny Indoor and 0.85 V in Pure Indoor, and rises about 0.1% per °C below 25 °C.
AlphaVis output scales with opacity: a panel that is 40% transparent (60% opaque) gives 60% of AlphaGlass's output.
AlphaGlass: rigid perovskite PV on glass. Module dimensions are limited to 450 × 300 mm.
Energy / day
Load covered
Battery life